Sharper peaks, better separations

PAL RTC / RSI / LSI Modules

PAL RTC / RSI / LSI Modules

PAL RTC/RSI Modules

Agitator:

  • For the incubation and agitation of samples
  • 6 positions for 20mL vials
  • Temperature range 30° - 200°C
  • Agitation  speed 250 - 750rpm
  • Optional adapter for 2mL or 10mL vials

Barcode Reader Module:

  • This Barcode Reader Module reads the barcode labels on 2mL, 10mL and 20mL vials regardless of the orientation on the vials. Therefore it ensures highest process safety and traceability
  • Reads horizontal 1 D barcodes
  • Two scanners allow identification of vials irrespective of position of the barcode
  • Works with 2mL, 10mL and 20mL vials

Centrifuges:

  • For the efficient centrifugation in automated workflows (e.g. protein precipitation, phase separation)
  • Full software control with PAL Sample Control
  • Control through many Chromatographic Data Systems
  • Relative centrifugal force: 
    2000 x g with Centrifuge Combi  
    5000 x g with Centrifuge 2 mL
  • Vial format: Centrifuge Combi: 
    2 mL (6 vials) + / 10 mL 
    20 mL (2 vials)
    Centrifuge: 2 mL (8 vials)

DeCapper Module:

  • opens/closes 2, 10, 20 mL screw cap vials without any change of hardware (no adapters required)
  • a defined torque guarantees the reproducible and leak-tight closing of headspace vials
  • PAL Re-Cap vials ensure consistent performance for multiple open/close cycles

Dilutor:

  • For efficient and accurate addition of larger amounts of liquids 
  • 100µL, 1mL (standard), 5mL & 10mL dispensing syringes available
  • Optional selector valves allow dispensing of up to 5 different liquids

Fast Wash Station:

  • Cleans syringes of  gauges  19 to 26
  • Integrated pumps for active wash solvent delivery
  • Supports two different wash solvents (e.g. aqueous and organic)
  • Reduced wash solvent consumption by automatic flow adjustments
  • Can be mounted underneath Valve Drives to minimize required space

Large Wash & Solvent Module:

  • Wash Module for large volume injections
  • 2x 100mL solvent vials
  • Waste port with connector for waste bottle
  • For the addition of larger volumes of solvents, e.g. to prepare serial dilutions
  • 3x 100mL solvent vials

Heatex Stirrer Module:

  • For powerful mixing and heating in sample prep and SPME Arrow
  • Temperature range 30° - 150°C
  • Stirring speed up to 1600 rpm (200 cycloidal loops)
  • Optimized for 20mL vials (for 10 mL vials special adapters are required)

SPME Arrow Conditioning Module:

  • For the conditioning of SPME Arrow and SPME fibers prior to sample enrichment, max. 350°C
  • Position for automated conditioning
  • Position for manual pre-conditioning
  • Automated purge gas valve
  • Manual gas valve for pre-conditioning
  • Replacement liners for easy maintenance

Standard Wash Station:

  • Wash Module for low volume injections
  • 4x 10mL wash solvent vials
  • 1x 10mL waste vial
  • Optional waste port  to connect a waste bottle

Valve Drive Module:

  • Universal Valve Drive Module for sample injection, column switiching for online LC-LC-MS or online SPE-LC-MS, multiplexing, column selection and many more. 
  • The Valve Drive Module supports VICI/Valco and Rheodyne valve types.
  • Injection port bottom sensing minimizing carryover
  • Constant Force Technology to reduce dead volume during injection process
  • UHPLC/HPLC: up to 50% faster switching times for optimum system performance and prolonged column life time
  • Stackable design to reduce the space demand and allow any flexible configuration
  • Huge flexibility to arrange multiple valve solutions
  • The Fast Wash Module is also stackable below a Valve Drive

Vortex Module:

  • For efficient mixing during liquid homogenization and extraction steps.
  • Magnetic transportation
  • Standard vial sizes: 2mL / 10mL / 20mL
  • One additional slot for custom size vials
  • Provides very efficient mixing

Trayholder & Stacks:

Peltier Stack 2DW Module

For the storage of two racks or plates under defined temperature conditions between 4°C and 40°C. Allows to use transparent standard vials with light sensitive compounds. A maximum of four Peltier Stacks can be configured on a PAL with extended x-axis length.

Capacity:

  • 2x MTP (Multi Titer Plate)
  • or 2x DW (Deep Well Plate)
  • or 2x VT15 (15 x 10mL)
  • or 2x VT54 (54 x 2mL) 
  • or 2x VT70 (70 x 1mL) 
  • or combinations
Peltier Stack 6DW Module
 
For the storage of six racks or plates under defined temperature conditions between 4°C and 40°C. Allows to use transparent standard vials with light sensitive compounds. A maximum of four Peltier Stacks can be configured on a PAL with extended x-axis length.Capacity:
  • 6x MTP (Multi Titer Plate)
  • or 6x DW (Deep Well Plate)
  • or 6x VT15 (15 x 10mL)
  • or 6x VT54 (54 x 2mL)
  • or 6x VT70 (70 x 1mL)
  • or combinations
Stack 6DW /12MT Module
For the storage of racks or plates at room temperature. Allows to store samples with light sensitive compounds. A maximum of four Stacks can be configured on a PAL with extended x-axis length.Capacity 6DW:
  • 6x MTP (Multi Titer Plate)
  • or 6x DW (Deep Well Plate)
  • or 6x VT15 (15 x 10mL)
  • or 6x VT54 (54 x 2mL)
  • or 6x VT70 (70 x 1mL)
  • or combinations
Capacity 12MT:
  • 12x MTP (Multi Titer Plate, shallow well)
Trayholder
 
The Trayholder offers sample storage at room temperature. A PAL with extended x-axis length can hold up to 7 Trayholders.Capacity:
  • 3x MTP (Multi Titer Plate)
  • or 3x DW (Deep Well Plate)
  • or 3x VT15 (15 x 10/20mL
  • or 3x VT54 (54 x 2mL)
  • or 3x VT70 (70 x 1mL)
  • or combinations
  • or 60x 10/20mL (with one R60 tray)

Want to know more about the PAL system? Please contact our experts for a tailored advice.

(The PAL system will be delivered through Axel Semrau)