PAL RTC / RSI / LSI Modules
PAL RTC/RSI Modules
Agitator:
- For the incubation and agitation of samples
- 6 positions for 20mL vials
- Temperature range 30° - 200°C
- Agitation speed 250 - 750rpm
- Optional adapter for 2mL or 10mL vials
Barcode Reader Module:
- This Barcode Reader Module reads the barcode labels on 2mL, 10mL and 20mL vials regardless of the orientation on the vials. Therefore it ensures highest process safety and traceability
- Reads horizontal 1 D barcodes
- Two scanners allow identification of vials irrespective of position of the barcode
- Works with 2mL, 10mL and 20mL vials
Centrifuges:
- For the efficient centrifugation in automated workflows (e.g. protein precipitation, phase separation)
- Full software control with PAL Sample Control
- Control through many Chromatographic Data Systems
- Relative centrifugal force:
2000 x g with Centrifuge Combi
5000 x g with Centrifuge 2 mL - Vial format: Centrifuge Combi:
2 mL (6 vials) + / 10 mL
20 mL (2 vials)
Centrifuge: 2 mL (8 vials)
DeCapper Module:
- opens/closes 2, 10, 20 mL screw cap vials without any change of hardware (no adapters required)
- a defined torque guarantees the reproducible and leak-tight closing of headspace vials
- PAL Re-Cap vials ensure consistent performance for multiple open/close cycles
Dilutor:
- For efficient and accurate addition of larger amounts of liquids
- 100µL, 1mL (standard), 5mL & 10mL dispensing syringes available
- Optional selector valves allow dispensing of up to 5 different liquids
Fast Wash Station:
- Cleans syringes of gauges 19 to 26
- Integrated pumps for active wash solvent delivery
- Supports two different wash solvents (e.g. aqueous and organic)
- Reduced wash solvent consumption by automatic flow adjustments
- Can be mounted underneath Valve Drives to minimize required space
Large Wash & Solvent Module:
- Wash Module for large volume injections
- 2x 100mL solvent vials
- Waste port with connector for waste bottle
- For the addition of larger volumes of solvents, e.g. to prepare serial dilutions
- 3x 100mL solvent vials
Heatex Stirrer Module:
- For powerful mixing and heating in sample prep and SPME Arrow
- Temperature range 30° - 150°C
- Stirring speed up to 1600 rpm (200 cycloidal loops)
- Optimized for 20mL vials (for 10 mL vials special adapters are required)
SPME Arrow Conditioning Module:
- For the conditioning of SPME Arrow and SPME fibers prior to sample enrichment, max. 350°C
- Position for automated conditioning
- Position for manual pre-conditioning
- Automated purge gas valve
- Manual gas valve for pre-conditioning
- Replacement liners for easy maintenance
Standard Wash Station:
- Wash Module for low volume injections
- 4x 10mL wash solvent vials
- 1x 10mL waste vial
- Optional waste port to connect a waste bottle
Valve Drive Module:
- Universal Valve Drive Module for sample injection, column switiching for online LC-LC-MS or online SPE-LC-MS, multiplexing, column selection and many more.
- The Valve Drive Module supports VICI/Valco and Rheodyne valve types.
- Injection port bottom sensing minimizing carryover
- Constant Force Technology to reduce dead volume during injection process
- UHPLC/HPLC: up to 50% faster switching times for optimum system performance and prolonged column life time
- Stackable design to reduce the space demand and allow any flexible configuration
- Huge flexibility to arrange multiple valve solutions
- The Fast Wash Module is also stackable below a Valve Drive
Vortex Module:
- For efficient mixing during liquid homogenization and extraction steps.
- Magnetic transportation
- Standard vial sizes: 2mL / 10mL / 20mL
- One additional slot for custom size vials
- Provides very efficient mixing
Trayholder & Stacks:
Peltier Stack 2DW Module
For the storage of two racks or plates under defined temperature conditions between 4°C and 40°C. Allows to use transparent standard vials with light sensitive compounds. A maximum of four Peltier Stacks can be configured on a PAL with extended x-axis length.
Capacity:
- 2x MTP (Multi Titer Plate)
- or 2x DW (Deep Well Plate)
- or 2x VT15 (15 x 10mL)
- or 2x VT54 (54 x 2mL)
- or 2x VT70 (70 x 1mL)
- or combinations
For the storage of six racks or plates under defined temperature conditions between 4°C and 40°C. Allows to use transparent standard vials with light sensitive compounds. A maximum of four Peltier Stacks can be configured on a PAL with extended x-axis length.Capacity:
- 6x MTP (Multi Titer Plate)
- or 6x DW (Deep Well Plate)
- or 6x VT15 (15 x 10mL)
- or 6x VT54 (54 x 2mL)
- or 6x VT70 (70 x 1mL)
- or combinations
Stack 6DW /12MT Module
For the storage of racks or plates at room temperature. Allows to store samples with light sensitive compounds. A maximum of four Stacks can be configured on a PAL with extended x-axis length.Capacity 6DW:
- 6x MTP (Multi Titer Plate)
- or 6x DW (Deep Well Plate)
- or 6x VT15 (15 x 10mL)
- or 6x VT54 (54 x 2mL)
- or 6x VT70 (70 x 1mL)
- or combinations
- 12x MTP (Multi Titer Plate, shallow well)
Trayholder
The Trayholder offers sample storage at room temperature. A PAL with extended x-axis length can hold up to 7 Trayholders.Capacity:
- 3x MTP (Multi Titer Plate)
- or 3x DW (Deep Well Plate)
- or 3x VT15 (15 x 10/20mL
- or 3x VT54 (54 x 2mL)
- or 3x VT70 (70 x 1mL)
- or combinations
- or 60x 10/20mL (with one R60 tray)
Want to know more about the PAL system? Please contact our experts for a tailored advice.
(The PAL system will be delivered through Axel Semrau)